Skip to content

Add Opta support #108

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Merged
merged 2 commits into from
Jan 16, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
3 changes: 3 additions & 0 deletions .github/workflows/compile-examples.yml
Original file line number Diff line number Diff line change
Expand Up @@ -51,6 +51,9 @@ jobs:
- fqbn: arduino:mbed_portenta:envie_m7
ethernet: false
nina: false
- fqbn: arduino:mbed_opta:opta
ethernet: true
nina: false

# Make board type-specific customizations to the matrix jobs
include:
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,75 @@
/*
Modbus RTU Client Parameters

This sketch is the same as ModbusRTUClientToggle and shows how to set
a few RS485 parameters.

Circuit:
- Arduino Opta
- GND connected to GND of the Modbus RTU server
- A(-) connected to A of the Modbus RTU server
- B(+) connected to B of the Modbus RTU server
*/

#include <ArduinoRS485.h> // ArduinoModbus depends on the ArduinoRS485 library
#include <ArduinoModbus.h>

constexpr auto baudrate { 19200 };

// Calculate preDelay and postDelay in microseconds as per Modbus RTU Specification
//
// MODBUS over serial line specification and implementation guide V1.02
// Paragraph 2.5.1.1 MODBUS Message RTU Framing
// https://modbus.org/docs/Modbus_over_serial_line_V1_02.pdf
constexpr auto bitduration { 1.f / baudrate };
constexpr auto wordlen { 9.6f }; // try also with 10.0f
constexpr auto preDelayBR { bitduration * wordlen * 3.5f * 1e6 };
constexpr auto postDelayBR { bitduration * wordlen * 3.5f * 1e6 };

void setup() {
Serial.begin(9600);
while (!Serial);

Serial.println("Modbus RTU Client Toggle w/ Parameters");

RS485.setDelays(preDelayBR, postDelayBR);

// start the Modbus RTU client in 8E1 mode
if (!ModbusRTUClient.begin(baudrate, SERIAL_8E1)) {
Serial.println("Failed to start Modbus RTU Client!");
while (1);
}
}

void loop() {
// for (slave) id 1: write the value of 0x01, to the coil at address 0x00
if (!ModbusRTUClient.coilWrite(1, 0x00, 0x01)) {
Serial.print("Failed to write coil! ");
Serial.println(ModbusRTUClient.lastError());
}

// wait for 0.5 second
delay(500);

// for (slave) id 1: write the value of 0x00, to the coil at address 0x00
if (!ModbusRTUClient.coilWrite(1, 0x00, 0x00)) {
Serial.print("Failed to write coil! ");
Serial.println(ModbusRTUClient.lastError());
}

// wait for 0.5 second
delay(500);

auto coil = ModbusRTUClient.coilRead(0x02, 0x00);

if (coil < 0) {
Serial.print("Failed to read coil: ");
Serial.println(ModbusRTUClient.lastError());
} else {
Serial.print("Coil: ");
Serial.println(coil);
}

// wait for 0.5 second
delay(500);
}
2 changes: 1 addition & 1 deletion library.properties
Original file line number Diff line number Diff line change
Expand Up @@ -6,6 +6,6 @@ sentence=Use Modbus equipment with your Arduino.
paragraph=Using TCP or RS485 shields, like the MKR 485 Shield. This library depends on the ArduinoRS485 library.
category=Communication
url=https://www.arduino.cc/en/ArduinoModbus/ArduinoModbus
architectures=megaavr,samd,mbed_nano,mbed_portenta
architectures=megaavr,samd,mbed_nano,mbed_portenta,mbed_opta
includes=ArduinoModbus.h
depends=ArduinoRS485