James reported:
> After e513cc1 module: Remove stop_machine from module unloading,
> module_refcount() is returning (unsigned long)-1 when called from within
> a routine that runs in module_exit. This is confusing the scsi device
> put code which is coded to detect a module_refcount() of zero for
> running within a module exit routine and not try to do another
> module_put. The fix is to restore the original behaviour of
> module_refcount() and return zero if we're running inside an exit
> routine.
The correct fix is to turn try_module_get() into __module_get(), and
always do the module_put().
Acked-by: James Bottomley <[email protected]>
Signed-off-by: Rusty Russell <[email protected]>