Original file line numberDiff line numberDiff line change
@@ -19,6 +19,8 @@ hardware:
1919

2020
Human-Machine Interfaces (HMIs) play a vital role in enabling effective interaction between operators and industrial systems, supporting efficient control, monitoring, and decision-making processes. By providing clear visualization and intuitive controls, HMIs enable operators to monitor system status and respond to issues in real time. For example, visual indicators for voltage levels can help operators identify and address potential problems before they impact operations.
2121

22+
HMIs can be implemented locally, via a dedicated hardware unit or via a server with thin clients. In this application note we will focus on the latter, due to a growing trend in adopting this approach for new industrial systems. We have chosen Ignition HMI software from the [Ignition Platform suite](https://inductiveautomation.com/ignition/), a powerful software that simplifies the creation of high-performance HMIs.
23+
2224
The functionality of HMIs depends on efficient and reliable communication across all connected components. This is achieved through the integration of robust communication protocols. One such protocol is Open Platform Communications Unified Architecture (OPC-UA), recognized for its flexibility, security, and compatibility with a wide range of automation platforms. Through OPC-UA, HMIs can ensure reliable data exchange and interoperability, further optimizing industrial system performance.
2325

2426
![HMI for Voltage Monitoring using OPC-UA System](assets/thumbnail.png)
@@ -760,4 +762,4 @@ This setup exemplifies the efficiency and reliability of using OPC-UA for secure
760762

761763
Now that you’ve explored the development of an intuitive HMI system using the Arduino Opta™ and the Ignition platform, it's time to dive deeper into the capabilities of the Arduino Pro ecosystem to enhance your industrial automation solutions. By integrating the Opta™ and Ignition into your professional setup, you can create scalable and intelligent systems for efficient process monitoring and control.
762764

763-
You can expand this application by adding new functionalities, such as incorporating additional sensors to monitor parameters like temperature, humidity, or pressure, enabling a more comprehensive analysis of your system. Consider utilizing the Ignition Perspective Module to extend the HMI to mobile devices for greater accessibility, or explore Ignition’s advanced features for alarm management and historical data analysis.
765+
You can expand this application by adding new functionalities, such as incorporating additional sensors to monitor parameters like temperature, humidity, or pressure, enabling a more comprehensive analysis of your system. Consider utilizing the Ignition Perspective Module to extend the HMI to mobile devices for greater accessibility, or explore Ignition’s advanced features for alarm management and historical data analysis.

0 commit comments

Comments
 (0)