### Setting Up the Arduino PLC IDE
92
92
93
-
To get the Arduino PLC IDE software, go to the [official software website](https://www.arduino.cc/pro/software-plc-ide)and choose to download the PLC IDE installer file. The software is named **`Arduino PLC IDE Installer`**.
93
+
To get the Arduino PLC IDE software, go to the [official software website](https://www.arduino.cc/pro/software-plc-ide)and choose to download the PLC IDE installer file. The software is named **`Arduino PLC IDE Installer`**.
94
94
95
95

Copy file name to clipboardExpand all lines: content/hardware/07.opta/opta-family/opta/tutorials/10.opta-modbus-tcp-plc-ide/assets/plcide_software_download.svg
Copy file name to clipboardExpand all lines: content/hardware/07.opta/opta-family/opta/tutorials/10.opta-modbus-tcp-plc-ide/content.md
+11-15
Original file line number
Diff line number
Diff line change
@@ -90,13 +90,13 @@ Having provided an overview of the entire process, we can now delve into the spe
90
90
91
91
### Setting Up the Arduino PLC IDE
92
92
93
-
Access the Arduino PLC IDE software by following [Arduino PLC IDE official website](https://www.arduino.cc/pro/software-plc-ide). You will have to download two executable files for proper software installation:
93
+
To get the Arduino PLC IDE software, go to the [official software website](https://www.arduino.cc/pro/software-plc-ide) and choose to download the PLC IDE installer file. The software is named **`Arduino PLC IDE Installer`**.

96
96
97
-

97
+
The software requires **Windows 10** or a newer operating system version for the x64 architecture.
98
98
99
-
The installation wizard will provide all the required drivers, libraries, and cores for development and install the **Arduino PLC IDE**.
99
+
The Arduino PLC IDE installer contains the IDE and all the required drivers, libraries, and cores. The following sections will help you install the software properly.
100
100
101
101
***For more details regarding Arduino PLC IDE setup, please take a look at [Arduino PLC IDE Setup and Board's License Activation](https://docs.arduino.cc/tutorials/portenta-machine-control/plc-ide-setup-license) tutorial.***
102
102
@@ -139,19 +139,15 @@ Opta™ can also be configured manually with a specific IP address using __Ether
139
139
140
140
***The __Ethernet.begin(ip, dns, gateway, subnet)__ method postpones initialization for 60 seconds when the RJ45 cable is found to be disconnected or when Ethernet settings, such as the IP address, are improperly configured. The __Ethernet.begin(NULL, ip, dns, gateway, subnet, connection_timeout)__ method can be used to extend initialization process and tweak the `connection_timeout` value. This parameter sets the timeout period for the Data Layer connection to be established.***
141
141
142
-
If the IP address for Opta™ is set manually, it is necessary to configure the Ethernet interface on your computer by introducing a manual IP address setting under *IPv4*. The information set under the IPv4 configuration follows the gateway setting. A stable connection with Opta™ using the PLC IDE is essential for project development. The following image shows a configuration example on Windows 11 operating system:
142
+
The virtual serial port will establish communication between the computer and Opta™ to develop in the Arduino PLC IDE environment. To pair with Opta™ device, activate the Modbus RTU feature and select the highest secondary USB port number by navigating to `On-line -> Set up communication`.
143
143
144
-

144
+

145
145
146
-
The configured IP address for Opta™ also serves to connect and develop within the Arduino PLC IDE environment. The Modbus TCP option must be activated and set with Opta™ device's assigned IP address by going to `On-line -> Set up communication`. The connection between Opta™ and the development environment can be verified with the`ping <Opta™ IP Address>` command using a terminal.
147
-
148
-

149
-
150
-
Keep in mind that the correct configuration is key to work with PLC IDE and Opta™. Once the properties of the Opta™ devices are correctly set, we will be able to seamlessly connect to Opta™ and monitor the states of both devices.
146
+
Remember that proper setup is vital when interfacing with the PLC IDE and Opta™. Once the Opta™ properties are all set, you can connect and monitor the status of both devices.
151
147
152
148
#### Modbus TCP Client and Server Mode
153
149
154
-
The image below shows the interface we'll encounter when accessing the Modbus TCP configuration panel in the PLC IDE.
150
+
The image below shows the interface we will encounter when accessing the Modbus TCP configuration panel in the PLC IDE.
155
151
156
152

157
153
@@ -160,9 +156,9 @@ There are two options on the Modbus TCP configuration panel:
160
156
- Modbus TCP Master
161
157
- Modbus TCP Slave always enabled. Unit Identifier: 255
162
158
163
-
If the "Modbus TCP Master" option remains unchecked, the role of a Modbus TCP Server with its designated Unit Identifier is automatically adopted by the Opta™ device. No attention needs to be given to the Unit Identifier in such cases. It is because communication with the appropriate Opta™ device is ensured by the configured IP address, even when the same Unit Identifier is shared among multiple devices.
159
+
If the **Modbus TCP Master** option remains unchecked, the role of a Modbus TCP Server with its designated Unit Identifier is automatically adopted by the Opta™ device. No attention needs to be given to the Unit Identifier in such cases. It is because communication with the appropriate Opta™ device is ensured by the configured IP address, even when the same Unit Identifier is shared among multiple devices.
164
160
165
-
When "Modbus TCP Master" is checked, both Client and Server roles are taken on by the Opta™ device. In this mode, precedence is given to the Client role. As a consequence, under the `Ethernet` configuration tab, the introduction of a *General Modbus Node* option can be observed, as will be detailed in the section that follows.
161
+
When **Modbus TCP Master** is checked, both Client and Server roles are taken on by the Opta™ device. In this mode, precedence is given to the Client role. As a consequence, under the `Ethernet` configuration tab, the introduction of a *General Modbus Node* option can be observed, as will be detailed in the section that follows.
166
162
167
163
#### General Modbus Node Configuration
168
164
@@ -232,7 +228,7 @@ The `cnt` status variable uses the following parameters:
232
228
233
229
With these settings ready, you need to go to `Resources -> Opta`, select the corresponding port, and begin the `Manual sketch download` process. Then you need to go to `On-line -> Set up Communication` and activate Modbus TCP with the assigned IP address for Opta™.
234
230
235
-

231
+

236
232
237
233
Proceed with `On-line -> Connect` and it will establish communication between your computer and the Opta™ server. If everything is fine, you will be able to observe the message found at the lower right corner of the PLC IDE software stating that it is connected.
0 commit comments