[PC-1640] Launch Opta Analog Expansion (#2085)
* valve-connection.png image updated * datasheet started * A little table update * A little table update * RTD section covered * Images pending * Pending I/O channels description * waiting images * structure almost ready * Minor updates * product.md updated * Minor Update * tech-specs updated * Features ready * step file added * tutoriales folder added * typo fixed * Features updated * Features updated 2 * icon update * SVG updated * rtd image added * datasheet update * illustration update * Analog Expansion Seccion * digital section covered * section titles added * Analog Voltage input section * Current input section * image update * current sensor 2.0 * current sensor 2.0 * RTD section started * typo * typo * typo * code update * RTD section started * RTD section ready * outputs section started * voltage output started * analog voltage out added * LED and final section started * LED section added * My final review * datasheet update * images added * typo * typo * Update content/hardware/07.opta/opta-family/opta-analog-exp/features.md Co-authored-by: Fr4ng <[email protected]> * Update content/hardware/07.opta/opta-family/opta-analog-exp/features.md Co-authored-by: Fr4ng <[email protected]> * Update content/hardware/07.opta/opta-family/opta-analog-exp/features.md Co-authored-by: Fr4ng <[email protected]> * minor patch review * certifications updated * Opta Expansions sections rearrange * Tables format update * headings fix * not used image deleted * paragraph edited * General Library note updated * General Library note updated * General Library note updated * PT100 fixed * PT100 fixed * PT100 updated * Input/output timing added * Francesca review addresed * Power more clear * Small format fixes, Revission row updated to launch date * store links * final rephrase * Julian final review fixes * Julian final review fixes * typo * Fix * Symbolic links fixed, seconday button revamped * Small icon fix * Store link updated --------- Co-authored-by: Christopher Mendez <[email protected]> Co-authored-by: Christopher Méndez <[email protected]> Co-authored-by: Fr4ng <[email protected]> Co-authored-by: jcarolinares <[email protected]>
1 parent 71239bc commit 6fffe5c

31 files changed

+2892
-302
lines changed
 
Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,5 @@
1+
software:
2+
- arduino-ide
3+
- arduino-cli
4+
- iot-cloud
5+
- plc-ide

‎content/hardware/07.opta/opta-family/opta-analog-exp/datasheet/assets/Opta_Digital_EXP_Block_Diagram.svg

Lines changed: 83 additions & 0 deletions
Loading
Loading
Loading
Loading
Loading

‎content/hardware/07.opta/opta-family/opta-analog-exp/datasheet/datasheet.md

Lines changed: 339 additions & 0 deletions
Large diffs are not rendered by default.
Binary file not shown.
Lines changed: 47 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,47 @@
1+
<FeatureDescription>
2+
3+
**Arduino Opta® Analog Expansions** are designed to multiply your Opta® micro PLC capabilities with the addition of eight programmable analog inputs for connecting your digital or analog sensors, allowing you to interface with voltage, current or resistive sensors, eight analog outputs for voltage or current and four PWM outputs.
4+
5+
Opta Analog Expansion allows professionals to scale up industrial and building automation projects while taking advantage of the Arduino ecosystem.
6+
7+
</FeatureDescription>
8+
9+
<FeatureList>
10+
11+
<Feature title="Configurability" image="configurability">
12+
13+
All the eight available channels can be configured by software as analog input or analog output. Two of those channels can get 3 wires RTD readings and the expansions have four additional PWM outputs, with a user-defined output voltage configurable from 8 to 40 VDC using the V<sub>PWM</sub> terminal.
14+
15+
</Feature>
16+
17+
<Feature title="Expandability" image="communication">
18+
19+
Up to five snap-on modules managed to multiply and mix your set of I/Os with seamless detection.
20+
21+
</Feature>
22+
23+
<Feature title="Industrial Temperature Range" image="temperature-sensor">
24+
25+
Arduino Opta® Analog Expansion has a highly reliable design operating at industrial temperature ranges (-20 °C to +50 °C).
26+
27+
</Feature>
28+
29+
<Feature title="Programming Languages Supported" image="file-icon">
30+
31+
* Arduino sketch
32+
* IEC-61131-3:
33+
* Ladder (LD)
34+
* Sequential Function Chart (SFC)
35+
* Function Block Diagram (FBD)
36+
* Structured Text (ST)
37+
* Instruction List (IL)
38+
39+
</Feature>
40+
41+
<Feature title="Suitable to DIN Rail" image="configurability">
42+
43+
Thanks to its form factor, it can be attached to a Din Rail mount system, providing quick access to all the I/O's.
44+
45+
</Feature>
46+
47+
</FeatureList>

‎content/hardware/07.opta/opta-family/opta-analog-exp/image.svg

Lines changed: 564 additions & 0 deletions
Loading
Lines changed: 13 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,13 @@
1+
---
2+
title: Opta Analog Expansion
3+
url_shop: https://store.arduino.cc/products/opta-ext-a0602
4+
url_guide: /tutorials/opta-analog-exp/user-manual
5+
primary_button_url: /tutorials/opta/user-manual#opta-analog-expansion
6+
primary_button_title: User Manual
7+
secondary_button_url: /software/plc-ide/
8+
secondary_button_title: PLC IDE Guide
9+
core: arduino:mbed_opta
10+
certifications: [FCC, CE, UKCA, cULus, ENEC]
11+
---
12+
13+
The **Arduino Opta® Analog Expansion** is a plug-and-play extension to the **Opta® PLC Controller** that expands its capabilities with more **inputs** with multiple functions such as digital, analog voltage, analog current or temperature and more **outputs** with analog voltage, analog current and PWM functionalities. Fully compatible with the Arduino Ecosystem.
Lines changed: 1 addition & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1 @@
1+
These are the technical specifications for Arduino Opta® Analog Expansion.
Lines changed: 32 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,32 @@
1+
Board:
2+
SKUs:
3+
Arduino Opta® Ext A0602: AFX00007
4+
Microcontroller:
5+
ID: Renesas R7FA4M1AB3CFM ARM® Cortex®-M4
6+
Cortex-M4 core: Up to 48 MHz
7+
Input:
8+
Configurable digital / analog inputs: 8x
9+
Digital operational range: 0-24 V
10+
Digital configurable threshold: Yes (supports 0-10 V logic)
11+
Analog resolution: 16 bit
12+
Analog input voltage range: 0-10 V
13+
Analog input current range: 0-25 mA
14+
Analog input resistance range: 0-1 MΩ
15+
Output:
16+
Configurable analog outputs: 8x, (2x used simultaneously max recommended)
17+
DAC resolution: 13 bit
18+
Analog output voltage range: 0-11 V
19+
Analog output current range: 0-25 mA
20+
PWM outputs: 4x
21+
PWM voltage output: 8-40 V
22+
Power:
23+
Input voltage: 12-24 VDC
24+
Dimensions:
25+
Weight: 130 g
26+
Width: 70 mm
27+
Length: 89 mm
28+
Height: 62 mm
29+
IP Protection: IP20
30+
Programming:
31+
Arduino programming language: Via Arduino IDE, Arduino CLI, Arduino Cloud
32+
IEC-61131-3: Ladder Diagram (LD), Function Block Diagram (FBD), Sequential Function Chart (SFC), Structured Text (ST), Instruction List (IL)
Lines changed: 1 addition & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1 @@
1+
../../../../07.opta/opta-family/opta/tutorials/01.user-manual
Loading
Loading
Loading
Loading
Loading
Loading
Loading
Loading
Loading

‎content/hardware/07.opta/opta-family/opta/tutorials/01.user-manual/content.md

Lines changed: 1807 additions & 302 deletions
Large diffs are not rendered by default.

0 commit comments

Comments
 (0)
Please sign in to comment.