Skip to content

Commit 13aa2aa

Browse files
authored
max current updated (#2188)
1 parent b58a203 commit 13aa2aa

File tree

3 files changed

+21
-20
lines changed

3 files changed

+21
-20
lines changed

content/hardware/07.opta/opta-family/opta-digital-exp/datasheet/datasheet.md

+8-7
Original file line numberDiff line numberDiff line change
@@ -23,7 +23,7 @@ There are two variants of the Arduino Opta® Digital Expansion created to fit th
2323
| ------- | -------------------------------------------------- | -------------------------------------------------- |
2424
| SKU | AFX00005 | AFX00006 |
2525
| Inputs | 16 x programmable (0-24 V digital / 0-24 V analog) | 16 x programmable (0-24 V digital / 0-24 V analog) |
26-
| Outputs | 8 x Electromechanical Relays (250 VAC - 6 A) | 8 x Solid State Relays (24 VDC - 2 A) |
26+
| Outputs | 8 x Electromechanical Relays (250 VAC - 6 A) | 8 x Solid State Relays (24 VDC - 3 A) |
2727

2828

2929
## Application Examples
@@ -44,7 +44,7 @@ Arduino Opta® Expansion is designed for industrial standard machinery control a
4444
| Antipolarity protection | Yes |
4545
| Overvoltage protection | Yes (+20%) |
4646
| Inputs | 16x Digital (0-24 V) / Analog (0-24 V) inputs |
47-
| Outputs | AFX00005: 8x Electromechanical Relays (250 VAC - 6 A), AFX00006: 8x Solid State Relays (24 VDC - 2 A) |
47+
| Outputs | AFX00005: 8x Electromechanical Relays (250 VAC - 6 A), AFX00006: 8x Solid State Relays (24 VDC - 3 A) |
4848
| Degree of Protection | IP20 |
4949
| Certifications | FCC, CE, UKCA |
5050

@@ -105,9 +105,9 @@ Arduino Opta® Expansion is designed for industrial standard machinery control a
105105
| Characteristics | Details |
106106
| ------------------------------------------- | --------------------------------- |
107107
| Number of outputs | 8x Solid State Relays (NO - SPST) |
108-
| Max current per relay | 2 A |
108+
| Max current per relay | 3 A |
109109
| Max peak current per relay | 50 A (10 ms) |
110-
| Continuous current per terminal | 2 A |
110+
| Continuous current per terminal | 3 A |
111111
| Short-circuit protection | No, external fuse required |
112112
| Relay rated voltage | 24 VDC |
113113
| Switching voltage range | 1.5...30 VDC |
@@ -149,7 +149,7 @@ Arduino Opta® Expansion is designed for industrial standard machinery control a
149149
| 3a | Power Supply Terminals 12...24 VDC |
150150
| 3b | I1...I16 digital/analog input terminals (0-24 V) configurable via IDE |
151151
| 3c | Power Status LED |
152-
| 3d | Relay Output Terminals 1...8, NO contact (SPST), EMR 6 A 250 VAC - SSR 2 A 24 VDC |
152+
| 3d | Relay Output Terminals 1...8, NO contact (SPST), EMR 6 A 250 VAC - SSR 3 A 24 VDC |
153153
| 3e | Status LEDs 1...8 |
154154
| 3f | Port for communication and connection of auxiliary modules |
155155

@@ -161,7 +161,7 @@ The following diagram explains the relation between the main components of the O
161161
![Block diagram](assets/Opta_Digital_EXP_Block_Diagram.svg)
162162

163163
### Relay Outputs
164-
Arduino Opta® Digital Expansions has eight *Normally Open* (NO) relays. For the **EMR** variant, eight powerful 6 A electromechanical relays capable of actuating on loads at a rated voltage of 250 VAC and up to a maximum switching voltage of 400 VAC, and for the **SSR** variant, eight fast 2 A solid state relays which are capable of actuating on DC loads at a rated voltage of 24 VDC.
164+
Arduino Opta® Digital Expansions has eight *Normally Open* (NO) relays. For the **EMR** variant, eight powerful 6 A electromechanical relays capable of actuating on loads at a rated voltage of 250 VAC and up to a maximum switching voltage of 400 VAC, and for the **SSR** variant, eight fast 3 A solid state relays which are capable of actuating on DC loads at a rated voltage of 24 VDC.
165165

166166
The relay *Maximum Peak Current* is defined as the highest value of inrush current that the relay can endure without undergoing any permanent degradation of its characteristics due to the generated heat. The relay has to be able to hold up that maximum using a duty cycle of less or equal to 10% and for a time equal to or less than 0.5 s.
167167

@@ -286,6 +286,7 @@ This device complies with part 15 of the FCC Rules. Operation is subject to the
286286
## Revision History
287287

288288
| Date | **Revision** | **Changes** |
289-
|------------|--------------|--------------------------------------|
289+
| ---------- | ------------ | ------------------------------------ |
290+
| 24/09/2024 | 3 | SSR operating current update |
290291
| 03/09/2024 | 2 | Cloud Editor updated from Web Editor |
291292
| 06/05/2024 | 1 | First Release |

content/hardware/07.opta/opta-family/opta-digital-exp/tech-specs.yml

+1-1
Original file line numberDiff line numberDiff line change
@@ -23,7 +23,7 @@ Relays:
2323
Nº of relays: 8
2424
Relay rated voltage: 24 VDC
2525
Relay maximum switching voltage: 33 VDC
26-
Maximum current per relay: 2 A
26+
Maximum current per relay: 3 A
2727
Maximum peak current per relay: 50 A
2828
Power:
2929
Input voltage: 12-24 VDC

content/hardware/07.opta/opta-family/opta/tutorials/01.user-manual/content.md

+12-12
Original file line numberDiff line numberDiff line change
@@ -1835,7 +1835,7 @@ In the image below there is an example of the power wiring of the expansions:
18351835

18361836
#### Programmable Inputs
18371837

1838-
The Opta™ Expansions have **16 analog/digital programmable inputs** accessible through terminals `I1` to `I16`.
1838+
The Opta™ Expansions have **16x analog/digital programmable inputs** accessible through terminals `I1` to `I16`.
18391839

18401840
Both Ext D1608E and Ext D1608S variant inputs can be used as **digital** with a 0-24 VDC range or as **analog** inputs with a 0-24 VDC range. The inputs are capable of operating with 0-10V analog sensors as well as 0-24V sensors.
18411841

@@ -2195,7 +2195,7 @@ Expansion[0]: type DIGITAL [Mechanical], I2C address: 11
21952195

21962196
#### Outputs
21972197

2198-
The Opta™ Expansions have **8 relay outputs** accessible through terminals pairs `1` to `8`.
2198+
The Opta™ Expansions have **8x relay outputs** accessible through terminals pairs `1` to `8`.
21992199

22002200
![Opta Digital Expansions outputs](assets/variants-emr-ssr-new.png)
22012201

@@ -2213,21 +2213,21 @@ Relay Output terminals are mapped as described in the following table:
22132213
| Relay 8 | 7 |
22142214

22152215

2216-
The **Ext D1608E (EMR)** variant features 8 electromechanical relays with the following characteristics:
2216+
The **Ext D1608E (EMR)** variant features 8x electromechanical relays with the following characteristics:
22172217

22182218
| **Characteristics** | **Details** |
22192219
|:-------------------------------------------:|:--------------------------------------------------:|
22202220
| Number of outputs | 8x Electromechanical Relays (Normally Open - SPST) |
2221-
| Max current per relay | 6A |
2222-
| Max peak current per relay | 10A |
2223-
| Continuous current per terminal | 6A |
2221+
| Max current per relay | 6 A |
2222+
| Max peak current per relay | 10 A |
2223+
| Continuous current per terminal | 6 A |
22242224
| Short-circuit protection | No, external fuse required |
22252225
| Relay rated voltage | 250 VAC |
22262226
| Relay Max voltage | 400 VAC |
22272227
| Rated load AC1 | 1500 VA |
22282228
| Rated load AC15 (230 VAC) | 300 VA |
2229-
| Breaking capacity DC1: 24/110/220V | 6/0.2/0.12A |
2230-
| Minimum switching load | 500mW (12V/10mA) |
2229+
| Breaking capacity DC1: 24/110/220V | 6/0.2/0.12 A |
2230+
| Minimum switching load | 500 mW (12 V/10 mA) |
22312231
| Max output line length (unshielded) | 100 m |
22322232
| Relay response time from state 0 to state 1 | 5 ms for relay output |
22332233
| Relay response time from state 1 to state 0 | 3 ms for relay output |
@@ -2236,14 +2236,14 @@ The **Ext D1608E (EMR)** variant features 8 electromechanical relays with the fo
22362236
| Relay mechanical durability | 10 million cycles (DC) |
22372237
| Relay electrical durability | 60 thousand cycles with a resistive load (AC1) |
22382238

2239-
The **Ext D1608S (SSR)** variant features 8 solid state relays with the following characteristics:
2239+
The **Ext D1608S (SSR)** variant features 8x solid state relays with the following characteristics:
22402240

22412241
| **Characteristics** | **Details** |
22422242
|:-------------------------------------:|:--------------------------------------------:|
22432243
| Number of outputs | 8x Solid State Relays (Normally Open - SPST) |
2244-
| Max current per relay | 2A |
2245-
| Max peak current per relay | 50A (10 ms) |
2246-
| Continuous current per terminal | 2A |
2244+
| Max current per relay | 3 A |
2245+
| Max peak current per relay | 50 A (10 ms) |
2246+
| Continuous current per terminal | 3 A |
22472247
| Short-circuit protection | No, external fuse required |
22482248
| Relay rated voltage | 24 VDC |
22492249
| Switching voltage range | 1.5...30 VDC |

0 commit comments

Comments
 (0)